Ultrasonic Thickness Gauge NOVOTEST UT-1M-IP

Ultrasonic Thickness Gauge NOVOTEST UT-1M-IP is a special version of ultrasonic thickness gauge, it is designed to measure the thickness of various materials and products for one-way access in difficult climatic conditions – in dusty rooms, in high humidity, in the rain – when the use of a conventional ultrasonic thickness gauge is impossible.

It is used to control the thickness of materials such as glass, metals and alloys, polymers, plastic and many others. Objects can be pipes, rolled products, structures, products and parts for various purposes and shapes.

 

 

 

NOVOTEST Lab is your real laboratory in your pocket! Optionally with UT-1M-IP (Lab) model only!

The results of measurement, adjustment and calibration of the ultrasonic thickness gauge in smartphone – the innovative NOVOTEST application for smartphones based on Android.

The functions of devices have no been so wide before! With the Bluetooth connection, your smartphone is able to control all the functionality of the NOVOTEST ultrasonic thickness gauge without wires. The intuitive interface of the application itself, access to the Internet, mail and instant messengers, touch screen, camera, microphone and GPS receiver of the mobile device make the use of NOVOTEST devices much more convenient and versatile.

More info about NOVOTEST Lab

The main advantages of the Ultrasonic Thickness Gauge NOVOTEST UT-1M-IP:

INCREASED DUST AND MOISTURE RESISTANCE

Unique protection against dust and moisture – by default, the device is delivered with a degree of dust and moisture protection IP65 according to DIN 40050. When ordering, versions of a thickness gauge with moisture protection up to IP67 are available (immersion in water is allowed).

UT-1M-IP thicknee gauge 1
UT-1M-IP thicknee gauge 2

UNPRECEDENTED AUTONOMY OF THE DEVICE

Due to the features of circuitry and operating modes – the continuous operation time of the device in practice reaches 200 hours. What makes the device ideal for field conditions in the absence of power supply.

WIDE RANGE OF MEASURING

Ultrasonic Thickness Gauge NOVOTEST UT-1M-IP can be equipped with various types of transducers, however, the device has the ability to advanced settings of transducers (gain, path, V-correction, etc.), which allows the user to get the maximum operation range with one transducer, in practice, the operating range of the 5 MHz probe reaches from 0.5 to 500 mm.

UT-1M-IP thicknee gauge 4

LIBRARY OF MATERIALS AND PROBES

The device has a library of velocities of basic materials, as well as an archive of transducers, which allows the operator to take measurements at various objects without additional reference information and complicated setup. Also, the user can independently replenish the settings archive.

TRANSFERRING DATA TO PC

The device allows user to record the measurement results in the archive of the device, and subsequently transfer them to a PC using special software – NOVOTEST.INFO/USB-connect. Device has special water-dustproff connecter and special cable in set.

Online-Archive NEW
  • Unique protection from dust and moisture, previously not available in the market of ultrasonic thickness gauges of general purpose. By default the device comes with a degree of dust-moisture protection IP65. This protection degree can be increased up to IP67 (submerged in water) at order
  • Unprecedented autonomy of the device – increased up to 200 hours continuous operation time of the thickness gauge
  • Special rubber lining on the side surfaces of the casing facilitates the convenient retention of the thickness gauge in the user’s hand
  • Device has light weight and dimensions, in comparison with similar protected thickness gauges
  • Saved data can be transmit to PC
  • Material selection and automatic setting of ultrasound velocity
  • Large graphic display of high contrast and backlight
  • Display of measured thickness in mm and inches
  • Convenient menu in the device
  • Wide choice of UT probes with preset settings in the device
  • Modes of statistical processing of measurements
  • Ability to restore factory calibrations
  • Ability to adjust all parameters of the acoustic path
  • Ability of further adjusting the user gain directly from the measurement mode
  • Wide range of testing
  • Mode of audible and visual alarm when leaving the established ranges
  • Wireless connection with Android gadgets via NOVOTEST Lab App (optionally with UT-1M-IP (Lab) model only)
  • Wide measurement range (0.4 to 1500 mm and more)
  • Available probes 1.25-10 MHz:
    – 1.25MHz probe (echo) 20/2 for substantial thicknesses or materials with exceptionally high signal attenuation
    – 2.0MHz probe (echo) 20/2 for large thicknesses or materials with high signal attenuation
    – 2.5MHz probe (echo) 12/2 for thick samples
    – 5MHz probe (echo) 10/2 for a wide range of basic samples
    – 10MHz probe (echo) 6/2 for thin samples
    – 10MHz probe (echo) 2х3 for products of complex shapes, usually turbine blades
    – 5MHz high-temperature probe (echo) 10/2 for heated samples up to 250 °С/482 °F
    – 2.5MHz probe (echo-echo) 12/2 for through coating
    – 5MHz probe (echo-echo) 10/2 for through coating
    – 10MHz probe (echo-echo) 6/2 for through coating
    – 5MHz probe (echo-echo) 10/2 for through coating, underwater, 10 m cable
    – 5MHz probe (echo-echo) 10/2 for through coating, underwater, 20 m cable
    – 5MHz probe (echo-echo) 10/2 for through coating, underwater, 30 m cable
  • Gain adjustment (±20 Db)
  • Preset velocities for many materials
  • B-scan and control modes
  • Through-coating (echo-echo) mode
  • Threshold setting with automatic alarm
  • Saving the settings for different probes
  • Compatibility with probes of other manufacturers
  • V-path correction and TVG adjusting for the user’s probes
  • Measurement storage and PC software
  • PC cable connection:
    – Online – NOVOTEST.INFO/USB-connect
    – Offline – NOVOTEST USB-Connect
  • Wireless connection with Android gadgets via NOVOTEST LAB App (only for UT-1M-IP (Lab))
Measuring thicknesses range on steel, mm:

  • Probe 10MHz – P112-10-2×3
  • Probe 10MHz – P112-10-6 / 2
  • Probe 5MHz – P112-5-10 / 2
  • Probe 2,5MHz – P112-2,5-12 / 2
  • Probe 2MHz – P112-2-20 / 2
  • Probe 1,25MHz – P112-1.25-20 / 2
0.4 to 1500 mm and more
(depending on material and surfaces)

  • 0.4-15
  • 0.45-300
  • 0.8-500
  • 2.5-1000
  • 3-1200
  • 4-1500
Probe dimensions, mm:

  • Probe 10MHz – P112-10-2×3
  • Probe 10MHz – P112-10-6 / 2
  • Probe 5MHz – P112-5-10 / 2
  • Probe 2,5MHz – P112-2,5-12 / 2
  • Probe 2MHz – P112-2-20 / 2
  • Probe 1,25MHz – P112-1.25-20 / 2
  • 4×9×60
  • D12×15
  • D17×20
  • D20×21
  • D30×28
  • D30×35
Dimensions of probe contact area/crystal, mm:

  • Probe 10MHz – P112-10-2×3
  • Probe 10MHz – P112-10-6 / 2
  • Probe 5MHz – P112-5-10 / 2
  • Probe 2,5MHz – P112-2,5-12 / 2
  • Probe 2MHz – P112-2-20 / 2
  • Probe 1,25MHz – P112-1.25-20 / 2
  • 2×7/2×3
  • D9/D6
  • D14/D10
  • D16/D12
  • D24/D20
  • D24/D20
Optional probes:

  • 5MHz high-temperature probe (echo) 10/2
  • 2,5MHz probe (echo-echo) 12/2 for through coating
  • 5MHz probe (echo-echo) 10/2 for through coating
  • 10MHz probe (echo-echo) 6/2 for through coating
  • 5MHz probe (echo-echo) 10/2 for through coating, underwater, 10 m cable
  • 5MHz probe (echo-echo) 10/2 for through coating, underwater, 20 m cable
  • 5MHz probe (echo-echo) 10/2 for through coating, underwater, 30 m cable
  • range 0,8 – 300 mm,
    surface temperature up to 250 °С/482 °F
  • range 6 – 30 mm,
    coating thickness range – up to 1 mm
  • range 3,5 – 26 mm,
    coating thickness range – up to 1 mm
  • range 2 – 12 mm,
    coating thickness range – up to 0,6 mm
  • range 3,5 – 26 mm,
    coating thickness range – up to 1 mm
  • range 3,5 – 26 mm,
    coating thickness range – up to 1 mm
  • range 3,5 – 26 mm,
    coating thickness range – up to 1 mm
Compatible probe types
  • Ultrasonic, dual-element, longitudinal waves
    (including probes of other manufacturers)
Compatibility with Active EMAT Transducer EMAT-A1 No
Probe calibrations (V-path, TVG, etc.)
  • factory for NOVOTEST probes
  • users for probes of other manufacturers
Probe cable connector type 2 Lemo 00
Probe cable length, m 1,2
Measurement scales
  • mm (m/s)
  • inch (inch/μs)
Measurement resolution, mm/inch 0.01/0.001
(0.01/0.0001 by request)
Basic measurement accuracy, mm ± (0,01 T+0.05)
(*For range 0.8 – 300 mm)
Gain range, dB ± 20
Response time, with no more than, s 1
Setting range of the ultrasonic velocity, m / s 1000-17000
Preset velocities for materials Steel (8 different grades), Aluminum, Iron, Cast Iron, Zinc, Chromium, Copper, Brass, Bronze, Silver, Gold, Nickel, Tungsten, Tin, Lead, Molybdenum, Manganese, Magnesium, Rubber, Polystyrene, Plexiglas, Capron, Caprolon,  ED-5, Ebonite, Porcelain, Teflon, Textolite, Silicate Glass, Acrylic glass, User
Operating modes
  • Normal
  • B-scan
  • Control mode
Standards
  • ASTM E797
  • EN 14127
  • EN15317
Body type /
Dust and moisture protection level
  • Plastic, sealed
  • IP65
  • Optionally water immersion up to 1m deep for 30 min (IP67)
Calibration thickness block on the body 6 mm (Steel/~6080 m/s)
PC cable connection
Wireless connection with Android gadgets via NOVOTEST Lab App
  • UT-1M-IP – No
  • UT-1M-IP (Lab) – Yes
Storage capacity of measurement results
  • UT-1M-IP – 128
  • UT-1M-IP (Lab) – 128 in the device + in NOVOTEST Lab App limited only by the memory of the Android gadgets
Measurement archives
Menu languages English, Spanish, Ukrainian, Russian (other languages optional)
Operating environment
  • Temperature:-20°C~50°C
  • Humidity: 30%~80%R.H.
Power supply DC 4.5V (3 pcs standard batteries AA)
Time of continuous work hours, not less, h up to 200
Charging 5V USB charger
Weight of electronic unit with batteries, no more, kg 0.2
Overall dimensions, mm 120x60x25
Package weight, kg 1.5
Package dimensions, cm 33*27*10
Documents
Country of origin Made in Ukraine (Europe)
Warranty
  • Basic
    – 12 months for electronic unit
    – 6 months for probes
  • Extended (optional)
    – up to 3 years

General comparative chart of all models NOVOTEST ultrasonic thickness gauges (without UT-3M-EMAT

 Model name UT-2A UT-1M UT-1M-IP UT-1M-ST
Measuring thicknesses range for steel, mm 0,4 – 1500 (depends on probe) 0,45 – 1500 (depends on probe)
Resolution, mm 0,01
Basic measurement accuracy, mm ± (0,01*T+0,05)
Basic probes / range for steel 2,5 MHz / 2,5 – 1000 mm
5 MHz / 0,8 – 300 mm
10 MHz / 0,45 – 75 mm
Optional probes / range for steel 1,25 MHz / 4 – 1500 mm
2 MHz / 3 – 1200 mm
High-temperature 5MHz (up to 250 °С) / 0,8 – 300 mm
Echo-Echo 5MHz for through-coating measurements / 3,5 – 26 mm
Compatibility with
Active EMAT Transducer EMAT-A1
Yes No
Compatible probe types Dual-element
Single-element
Dual-element
Operating modes Normal
A-scan
B-scan
Manual mode
Control mode
Normal
B-scan
Control mode
Measurement methods Echo
Echo-Echo
Peak-Peak
Zero-crossing
Echo
Echo-Echo
Measurement units mm
inch
Display Color, 3,5 inch, 480*320 Monochrome, 2,5 inch, 128*64
Menu languages English
Ukrainian
Russian
(other languages optional)
English
Spanish
Ukrainian
Russian
(other languages optional)
Body type/
Dust and moisture protection level
Metal, durable /Standard for shop and field operation Plastic, with shockproof silicone case / Standard for shop and field operation Plastic, sealed /High – optionally water immersion up to 1m deep for 30 min Metal, durable /Standard for shop and field operation
Saving of the settings for different probes Yes
Compatibility with probes of other manufacturers Yes
V-path correction and TVG adjusting for the user’s probes Yes
Storage of measurement results 7000 and more
(Limited only by the memory card)
128 128 128
PC cable connection
(via www.novotest.info)
Yes
Smartphone Wireless connection
(via NOVOTEST Lab)
No Optional Optional No
Charger type Any USB socket (charger adapter, PC, power bank, etc.) External charger for batteries Any USB socket
(charger adapter, PC, power bank, etc.)
External charger for batteries
Battery Built-in Li-ion 2pcs standard
АА batteries
3pcs standard
АА batteries
2pcs standard
АА batteries
Electronic unit weight, no more, kg 0,5 0,25 0,35 0,35
Dimensions (L x W x H), mm 165x90x50 122х76х37 160х90х28 130х90х40
Minimum time of continuous work, h 10 25 25 25
Operating temperature range, ° C -20 to +40
  • – UT-1M-IP (Lab) – with Wireless connection to Android gadgets via NOVOTEST Lab App
    – UT-1M-IP – basic model
  • Couplant
  • Calibration certificate issued by the Independent metrology laboratory
  • Certificate of origin issued by the Chamber of Commerce and Industry
  • UT-probes

– 1.25MHz probe for thickness gauge 20/2
– 2.0MHz probe for thickness gauge 20/2
– 2.5MHz probe for thickness gauge 12/2
– 5MHz probe for thickness gauge 10/2
– 10MHz probe for thickness gauge 6/2
– 10MHz probe for thickness gauge 3х2
– 5MHz probe for thickness gauge (echo-echo) 10/2
– 10MHz probe for thickness gauge (echo-echo) 6/2
– 5MHz high-temperature probe for thickness gauge 10/2
– 5MHz probe for thickness gauge (echo-echo) 10/2, underwater, 10 m cable
– 5MHz probe for thickness gauge (echo-echo) 10/2, underwater, 20 m cable
– 5MHz probe for thickness gauge (echo-echo) 10/2, underwater, 30 m cable

Thickness nominals Material
1-3-5-7-10-15 mm Steel, SS, Aluminum
1-2-3-4-5-6-7-8-9-10-11-12-13-14-15 mm Steel, SS, Aluminum
2,5-5-7,5-10-12,5 mm Steel, SS, Aluminum
2,5-5-7,5-10-12,5-15-17,5-20 mm Steel, SS, Aluminum
2,5-5-7,5-10-12,5-15-20 mm Steel, SS, Aluminum
2.5-5-10-20 mm Steel, SS, Aluminum
2-3-4-5-6-7-8-9-10 mm Steel, SS, Aluminum
2-3-4-5-6-7-8-9-10-11 mm Steel, SS, Aluminum
2-4-6-8-10 mm Steel, SS, Aluminum
2-4-6-8-10-12 mm Steel, SS, Aluminum
2-5-10-15-20-25 mm Steel, SS, Aluminum
2-5-10-20-30-40 mm Steel, SS, Aluminum
3-4-5-6-7-8-9 mm Steel, SS, Aluminum
4-6-8-10-12-15 mm Steel, SS, Aluminum
5-10-15-20-25-30 mm Steel, SS, Aluminum
5-10-15-20-25 mm Steel, SS, Aluminum
5-10-15-20-30-40 mm Steel, SS, Aluminum
5-10-15 mm Steel, SS, Aluminum
5-10-20 mm, step 0.1 Steel, SS, Aluminum
5-10-20-30-40-50 mm Steel, SS, Aluminum
10-11-12-13-14-15 mm Steel, SS, Aluminum
10-20-30-40-50 mm Steel, SS, Aluminum
10-20-40-60-80-100 mm Steel, SS, Aluminum
  • Reference Thickness Blocks
0,2 mm Steel, SS, Aluminum
0,3 mm Steel, SS, Aluminum
0,4 mm Steel, SS, Aluminum
0,5 mm Steel, SS, Aluminum
0,8 mm Steel, SS, Aluminum
1 mm Steel, SS, Aluminum
1,5 mm Steel, SS, Aluminum
2 mm Steel, SS, Aluminum
3 mm Steel, SS, Aluminum
4 mm Steel, SS, Aluminum
6 mm Steel, SS, Aluminum
10 mm Steel, SS, Aluminum
15 mm Steel, SS, Aluminum
20 mm Steel, SS, Aluminum
25 mm Steel, SS, Aluminum
30 mm Steel, SS, Aluminum
40 mm Steel, SS, Aluminum
50 mm Steel, SS, Aluminum
75 mm Steel, SS, Aluminum
90 mm Steel, SS, Aluminum
100 mm Steel, SS, Aluminum
125 mm Steel, SS, Aluminum
150 mm Steel, SS, Aluminum
175 mm Steel, SS, Aluminum
200 mm Steel, SS, Aluminum
300 mm Steel, SS, Aluminum
  • Electronic unit Ultrasonic Thickness Gauge UT-1M-IP/UT-1M-IP (Lab)  
  • Probe/transducer (echo) – 1 pc for choice
    (2.5MHz, 5MHz or 10MHz)
  • Accessory package:
    – AA batteries – 3 pcs
    – 5V USB charger
    – USB cable for PC
    – PC software:
    — Online – NOVOTEST.INFO/USB-connect
    — Offline – NOVOTEST USB-Connect
    – NOVOTEST LAB App for Android gadgets
    (for UT-1M-IP (Lab) only)
    – Operating manual/Quick guide
    – Transportation plastic case
UT-1M-IP em

Ultrasonic Thickness Gauge NOVOTEST UT-1M-IP underwater dive.Ultrasonic Thickness Gauge NOVOTEST UT-1M-IP underwater dive.